How to test bonds » Cold Bump Pull (CBP) » jaw quality

...this is page 3; click here to go to page 2.

CBP Jaw qualityCBP Jaw quality

6. Jaw quality

To reform and grip a ball with the maximum force possible the jaw quality must be maintained.

It is important to monitor jaw quality during use.

CBP jaws must align - view looking from the bottom and at the two ends of the jawsCBP jaws must align - view looking from the bottom and at the two ends of the jaws

The two jaws must also align as good as possible.

The maximum error of any misalignment side to side and in closing height is 5% of the ball diameter.

Cavity contamination is also a cause of poor jaw quality that can reduce the grip force. See the section on jaw cleaning.

Maximum error of any misalignment side to side and in closing height is 5% of the ball diameterMaximum error of any misalignment side to side and in closing height is 5% of the ball diameter

Continue to read:

Previous page: Objectives / Jaw size

Next page: Setting up and doing a test


© 1999-2016 XYZTEC BV Disclaimer, Privacy, Cookies